Sensor Core
Sensirion SHT40
Swiss Micro-Sensor Precision
Uncontrolled temperature fluctuations and unmonitored humidity spikes degrade perishable food inventories, ruin pharmaceutical batches, cause condensation-driven electrical short circuits, and reduce building energy efficiency. Traditional wired sensors demand costly cabling runs and inflexible duct retrofitting.
UniConverge Technologies engineered the UCT LoRaWAN® sensor to bridge the gap between bench-grade laboratory precision and heavy industrial survivability. Embedded with Sensirion’s CMOSens® SHT40 silicon engine, the unit captures real-time atmospheric dynamics with absolute repeatability.
LoRaWAN® Class A with ADR: Dynamically adjusts transmission data rate to conserve power and reduce packet collision.
Sensirion SHT40 Core: Ultra-precise NIST-traceable sensor element with integrated digital signal conditioning.
Dual Antenna Options: Standard internal omni-directional antenna or external SMA high-gain antenna for basement installations.
Configurable Reporting Logic: Periodic syncs (1 min to 24 hrs) paired with instant event triggers when thresholds breach safe bounds.
Modular Mounting Kits: Out-of-the-box hardware supports flat wall bracket fastening, pole strapping, and DIN rail clipping.
Engineered to dramatically lower Total Cost of Ownership (TCO) across distributed facilities while maintaining strict regulatory traceability.
End-to-End System Flow
From micro-second silicon sampling on the physical sensor probe to enterprise notification engines, UniConverge ensures unbroken data integrity and low latency.
Deployment Profiles
Engineered to adapt seamlessly across extreme cold chains, sensitive cleanrooms, high-humidity vertical farms, and heavy industrial automation plants.
Manufacturing
Track manufacturing floors, assembly bays, and raw chemical storage to avoid moisture condensation on high-tolerance metalwork.
Tolerance: ±0.2°C • IP65
Logistics & Pharma
Continuous thermal logging down to -40 °C inside refrigerated reefers, cold rooms, vaccine chillers, and meat processing facilities.
Operating: Down to -40°C
Supply Chain
Safeguard paper products, packaged foods, grain bins, and moisture-sensitive textiles from mold spores and thermal spoilage.
Range: 0–100% RH Guard
Data Infrastructure
Deploy high-density thermal mapping across hot/cold aisle containments, high-voltage battery banks, and raised-floor switchgear.
ASHRAE Thermal Compliance
BMS Integration
Stream wireless air temperature and humidity metrics straight into building automation systems to balance chillers and save energy.
BACnet / Modbus Gateway
Agritech
Optimize Vapor Pressure Deficit (VPD) in high-yield vertical farms, polyhouses, mushroom cultivation rooms, and outdoor orchards.
Solar / Sintered Protected
Utilities
Continuous monitoring inside chlorination dosing rooms, pump switch houses, and water treatment galleries prone to damp condensation.
IP65 Jet-Proof Gasket
GMP Validation
Support 21 CFR Part 11 and ISO 14644 compliance with NIST-traceable sensor readings for vaccine storage, sterile suites, and cleanrooms.
Traceable Audit Logs
Verified under rigorous environmental testing chambers following BIS, DoT, and CE industrial IoT compliance standards.
| LoRaWAN Protocol | Class A, v1.0.3 / v1.0.4 compatible |
|---|---|
| Activation Method | OTAA (Over-the-Air) & ABP supported |
| Frequency Bands | IN865 (865–867 MHz) • EU868 • US915 • AS923 |
| Transmit Power (TX) | Up to +20 dBm (configurable via ADR) |
| Receiver Sensitivity | -137 dBm @ SF12, 125 kHz |
| Communication Range | Up to 15 km Line-of-Sight / 3 km Urban |
| Internal Power Source | 19 Ah 3.6V Li-SOCl2 D-Cell (ER34615) |
|---|---|
| Battery Autonomy | Up to 10 Years* (15-min interval, SF7) |
| Deep Sleep Current | < 5 µA ultra-low leakage |
| TX Active Current | < 120 mA @ +20 dBm output |
| Battery Status Reporting | Real-time voltage & % telemetry in payload |
Engineering Inquiries
Answers to technical, integration, and operational queries from enterprise deployment engineers.
It is a Class A wireless node that measures temperature and relative humidity, then sends the readings over a LoRaWAN network. This UCT sensor uses a Sensirion SHT40 probe for industrial indoor, outdoor, and cold-chain monitoring.
Typical range is up to 15 km line-of-sight and about 3 km in urban conditions. Receiver sensitivity is -137 dBm at SF12, 125 kHz, with transmit power up to +20 dBm via ADR.
Yes. The enclosure is IP65, UV-resistant, and flame-retardant polycarbonate/ABS, with a sintered stainless-steel probe filter. It is built for outdoor sites, plant rooms, and damp industrial spaces.
A 19 Ah 3.6V Li-SOCl2 D-cell (ER34615) supports up to 10 years at a 15-minute reporting interval and SF7. Deep-sleep current stays under 5 µA.
Yes. LoRaWAN downlinks can change the reporting interval, alert thresholds, and data rate, and can reboot the node, without taking it off the wall. The interval is also OTA configurable.
Temperature from -40°C to +125°C (±0.2°C typical from 0°C to +60°C) and relative humidity from 0 to 100% RH, non-condensing (±1.8% RH typical at 25°C, 20–80% RH). Each payload also includes battery voltage and state of charge.
IN865 (865–867 MHz), EU868, US915, and AS923. Activation is OTAA or ABP on LoRaWAN Class A, versions 1.0.3 and 1.0.4.
Enterprise Evaluation
Deploy reliable wireless environmental monitoring across industrial, commercial, and remote locations. Request evaluation sample units or enterprise volume pricing today.
Complete the inquiry form below. Our IoT applications engineering team will review requirements and respond within 4 business hours.